CBL 21: EndoSequence Reciprocating (ESR) File. A clinical case and technique.

Allen Ali Nasseh   uploaded 5 years ago

The newly released ESR Files are similar to WaveOne Gold files. The one difference is that they can be resterilized and are less expensive. Since they can be reused, we’ve developed a protocol for their use that allows them to place less pressure on dentin walls and therefore be safer for both the file and the tooth. Dr. Nasseh explains this protocol and technique.

Comments

Home Forums CBL 21: EndoSequence Reciprocating (ESR) File. A clinical case and technique.

Viewing 3 reply threads
  • Author
    Posts
    • #1094
      Allen Ali Nasseh
      Keymaster

      During a short visit to Toronto, Dr. Nasseh shares a clinical case of a mandibular molar he treated using the newly released ESR Files.
      [See the full post at: CBL 21: EndoSequence Reciprocating (ESR) File. A clinical case and technique.]

    • #4257
      drmaloux
      Participant

      How long do you have to wait for the Bc sealer to set before you can use the ultrasonics scaler to remove the excess sealer on canal walls before the endosequence base ?

    • #4258
      Allen Ali Nasseh
      Keymaster

      There’s no wait. You remove it before it sets using ultrasonic and water that will wash it out. Jus make sure you have the GP spread well over the orifice so sealer from inside the canal is not washed out. Cheers!

    • #4755
      DrASeuss91
      Participant

      How do you proceed if you’re estimated WL was long, and you go further than you wanted with the 25/20/scout? Do you just open to a larger size with the final WL to create an apical stop?

Viewing 3 reply threads
  • You must be logged in to reply to this topic.
Endodontic Educational Seminars, LLC (DBO Real World Endo)
Nationally Approved PACE Program Provider for FAGD/MAGD credit.
Approval does not imply acceptance by
any regulatory authority or AGD endorsement.
01/01/2022 to 12/31/2027
Provider ID# 217877